Technical Specifications & In-House Equipment

Technical Specifications

1 x 1000/1000MB UFB Vodafone Fibre Connection

1 x 200/200 MB Kordia Fibre Connection

Hardware

  • Ubiquiti UniFi UAP-AC-PRO Dual-band AC1750 throughout the venue
  • Ubiquiti Unifi Cloud Controller and  Security Gateway
  • 2,400sq/mJunckersUnobat 50 & 62 sprung floor systems
  • As a maximum, no overall load should exceed 1000kg on any m² of floor area
  • All vehicles must be approved by Operations Manager prior to floor access
  • Pneumatictyredwheels are best, no hard surfaced wheels should be rolled across the floor – clean & soft rubber or polyurethane outer surface
  • Any cars, vans or small trucks (up to 2,500kg) can drive slowly – 5km/hrover the flooras long as there is a minimum of four rubber tyred pneumatic wheels and carpet is laid on top of the floor for protection
  • Vehicles up to 4,000kg may be used on the floor, depending on the wheel configuration,with a minimum of 20mm plywood sheets on top of the floor.
  • The noise (rating) level from any activity (including sound checks), as measured at theboundary of any site in a residential zone, must not exceed the noise limits in the table below.
  • Noise limits must be measured in accordance with NZS 6801:2008 Acoustics –Measurement of Environmental Sound and assessed in accordance with NZS 6802:2008 Acoustics –Environmental Noise.
  • For special noise events an adjustment must not be applied to amplified music or amplifiedvoice sounds containing special audible characteristics (with respect to section 6.3 ofNZS6802:2008) but other sources of sound may have an adjustment applied if necessary in accordance with the same section.
  • The prescribed time frames for the purpose of assessment according to NZS6802:2008 mustbe the timeframe for which anyparticular noise limit applies.
  • Crowd noise is to be excluded from any assessment of compliance with these limits.
  • Aeq(5min), is specified, no 5-minute measurement sample can exceed the stated limit.

Time, day, duration and frequency Noise limit
Up to 20 special noise events in any 12 month period
60dB LAeq
(5min)
Up to 6 special noise eventson a Friday or Saturday finishing by 10:30 in any 12 month period
75dB LAeq
(5min)
General noise standards between 7:00am and 6:00pm
55dB LAeq
General noise standards between 6:00pm and 11:00pm
50dB LAeq
General noise standards between 11:00pm and 7:00am
45dB LAeq

*insert supply floor plan 

Access & Loading Bay 

  • Access via Green Room, directly intoSouth Westerncarpark area
  • External door 2800W x 2900H. Concrete Pad out to edge of Court 4
  • Maximum 1000kg safe working load limit
  • Catwalk access with safety lines in internal roof space to approved contractors. 
  • Rigging Plans must be signed off byEventfindaStadium engineer (any costs associated is client responsibility) 

*insert floor plan

  • Main Stadium (2 units) 3m x 4m LED (3.9mm SMD LED Screen @ 1920 x 1080 run frombothvideopro score system and a single HDMI or SDI input. 
    • All images are scaled to fit 16:10 ratio
    • Screens are to be apart of VHA. Screen operator not included
  • Foyer (1 unit) 3m x 4m (4mm SMD LED) Screen @ 1920 x 1080 resolution run from 
  • All events are given a 6-week advertising window prior to their event. As part of the venue hire, clients are allocated up to 30 seconds of video time and 1 static image slide free of charge
  • Screen runs every day and is exposed to approximately 1,000 people per day
  • External (1 unit) 3.6m x 1.9m
  • Image slots are available through Aurora Digital 
  • Vision Mixer available to hire
  • Data projector & speakers available to hire
  • PA System: Main Stadium PA system with 1 x Wireless Mic’s and central speaker clusterlocated above main stadium floor 

In-House Equipment

Our foyer features a state of the art 12m (4mx3m) led screen. This is capable of showing all manner of inputs from laptop displays to video files and even live streams if you wish.

This screen is in operation every day of the year between 8am and 11pm every day. With an average of more than 1,200 people per day walking past the screen this is a key way we keep our community updated and support your events.

As part of booking your event here you are allocated up to 30 seconds of video time and 1 static image slide free of charge. Only events that are held at our venue are able to be advertised and we reserve the right to approve any content prior to its installation.

Due to the scheduling of the screen all images in the “image set” listed on the screen specifications (Here) are required before we can install your content on the screen.

You can purchase additional 30 second video or image  slots on the screen in the lead up to your event for $150 per month per slot.

Specific Use During Events​

The screen is available in a number of ways to support your event on show day;

  • Exclusive use (for sponsors etc) $400 per day with only your content.
  • 30 second HDMI input Interspersed (with our content)  $150 per day.
  • Use specific use of the screen requires at least 14 days notice and inputs to be provided to us no less than 7 days prior to your event. These fees do not include a technician to operate the screen if required. This is not usually needed.

Please see your event coordinator for details on how to book the screen.

Specific image specifications for the screen are available on request.

In addition to the hire of our quality venue, we can provide:

  • Access to phone lines
  • Mobile EFTPOS
  • Super-fast wired and wireless broadband internet
  • Public catering options (in-house or off-site)
  • Table hire (200+ on-site)
  • Chair hire (800+ on-site)
  • In-house carpet

Venue Layouts

Sport Layouts

Expo Layouts